Clinical and Regulated

What’s new in FCS Express 7 IVD for Clinical and Validated Laboratories

In This Video

FCS Express 7 IVD 7.32.0070 is here with new enhancements designed to make clinical and validated workflows more efficient! This webinar is specifically for clinical diagnostic laboratories and anyone working in a GxP/GMP validated environment.

Learn about

  • Dynamic Markers: a new automatic peak-finding tool for histograms
  • Improvements to security and logging features, including new functionality with electronic signatures
  • New/Updated Instrument Specific Settings (ISS) for the BD FACSDiscoverTM A8/S8, Beckman Coulter CytoFLEX / DxFLEX, and Cytek Aurora-Evo
  • New and improved statistical and QC reporting capabilities for compensation matrices and data file-derived statistics grids
  • Performance improvements designed to help speed up layouts

From Design to Data: Building and Validating a 23 Color Spectral B NHL Panel for the Clinical Lab

In This Video

This webinar presents the end to end development and validation of a 23 color spectral flow cytometry panel for B cell non Hodgkin lymphoma (B NHL). Attendees will gain an inside look at the panel design process, including fluorophore selection, marker prioritization, and the trial and error optimization required to balance resolution, spreading error, and biological relevance. The session will detail the analytical validation of the panel — covering accuracy, precision, sensitivity, and specificity — and demonstrate how these metrics were established using real experimental data. We will also introduce a custom analysis template that incorporates the high dimensional tools UMAP and FlowSOM, showing how these approaches enhance population discovery and improve workflow in complex hematopathology panels.

Learn How To

  • Identify the criteria used to select fluorochromes and prioritize markers when designing a 23-color spectral B-NHL panel.
  • List the four analytical validation parameters: accuracy, precision, sensitivity, and specificity, and describe how each is measured to confirm clinical panel performance.
  • Describe how UMAP and FlowSOM are used within a custom analysis template to identify and characterize cell populations in high-dimensional spectral flow cytometry data

SOPs based analysis

In This Video

Clinical labs performing diagnostic testing or labs functioning in 21 CFR Part 11 regulated environments need to ensure the quality of their flow cytometry results, but this can often be a tedious and time-consuming manual process. FCS Express 7 includes many tools to enhance, streamline, and automate quality checks throughout the entire process from analysis to report generation. This webinar will discuss how De Novo Software provides the quality assurance you need with our new ISO 13485:2016 and ISO/IEC 27001:2022 certifications. We will also present an overview of some of the readily available tools to help labs ensure reproducibility and quality results.

Learn How To

  • Verify the Proper Installation and Operation with IQ/OQ Validation
  • Use SOPs as Training and Competency Tools for Analysts
  • Incorporate Features of FCS Express for Quality Control

Focus on Quality Results with FCS Express 7 (Full video)

In This Video

Labs performing diagnostic or clinical flow assays need to ensure the quality of their patient results, but this can often be a tedious and time-consuming manual process. The Clinical Edition of FCS Express 7 includes many tools to enhance, streamline and automate quality checks throughout the entire process from analysis to report generation. This presentation provides an overview of some of the readily available tools to ensure reproducibility and quality results using FCS Express. We start off covering essential elements like tokens, alerts, statistical classifiers, authorization, and permission rules; build up to more complex examples of SOP controlled layouts, 21 CFR Part 11 features (security & logging), IQ/OQ validation procedures and finish with newer elements like integrated Levey Jennings plots.

Learn How To

  • Verify the Proper Installation and Operation with IQ/OQ Validation
  • Use SOPs as Training and Competency Tools for Analysts
  • Incorporate Features of FCS Express for Quality Control

Quality for regulated lab environments: Meeting CFR 21 Part 11 compliance with FCS Express

In This Video

Following Good Laboratory Practice (GLP) is essential in regulated environments and your software used for flow cytometry data analysis and reporting should not be an exception. FCS Express helps labs that need to ensure the quality and integrity of their analysis workflow by offering unique features made to satisfy CFR 21 Part 11 compliance, including security and logging/audit trails. FCS Express is designed to help provide uniformity and consistency for flow cytometry data analysis within your lab, across sites, and for your clients by working in a software environment where every action and permission can be controlled at the user and analysis template level. When reproducible results are key to your workflow for flow or image cytometry based analysis FCS Express should be your tool of choice. Make sure to watch this special webinar especially if you are working in GMP, Cell Therapy, and other lab environments where quality, consistency, and documentation is key.

Learn How To

  • Use FCS Express to Meet CFR 21 Part 11 Compliance
  • Access Logging/Audit Trails
  • Incorporate Security Features

21 CFR Part 11 Features

In This Video

View this webinar to learn all about the FCS Express Security System, with over 300 permissions, extensive reporting, electronic signatures, and more. FCS Express provides comprehensive functionality for your security and 21 CFR Part 11 requirements.

Learn How To

  • Establish User and Layout Security
  • Add and Insert Electronic Signatures
  • Review the Audit Trail

Visibility, Authorizations, and Locking in FCS Express 7

In This Video

Explore the Visibility, Authorization, and Locking capabilities in FCS Express 7. With Visibility, learn how to hide or show objects, gates, quadrants, and markers. Allow or deny access to certain features with Authorizations and Locking. Or use custom expressions to control these features conditionally based on token values. Watch this webinar and learn how to get the most out of Visibility, Authorization, and Locking in FCS Express!

Learn How To

  • Control Visibility of Objects, Plots, and/or Pages
  • Enable or Disable Select or Edit Authorizations
  • Lock Gates to Prevent Moving or Editing

FCS Express IVD

In This Video

You will learn about new features and capabilities in FCS Express Clinical Edition that will enhance your data analysis.

Learn How To

  • Export to an Integrated Spreadsheet within an FCS Express Layout
  • Enable FCS Express to Remember Manually Set Scaling
  • Implement System Level Audit Trails

Clinical Features of FCS Express

In This Video

In this presentation, we will provide an overview of some of the readily available tools to ensure reproducibility and quality results using FCS Express. We will start off covering basic elements like tokens, alerts, statistical classifiers, authorization and permission rules; build up to more complex examples of SOP controlled layouts, 21 CFR Part 11 features (security & logging), IQ/OQ validation procedures and finish with newer elements like integrated Levey Jennings plots.

Learn How To

  • Define Security Group Permissions
  • Set Permissions for a Specific Layout
  • Work with Electronic Signatures and Audit Trails